Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Goodmorning, I write this message because I have some problems with a compactRIO. Options. This document describes the range of software versions required for the aforementioned devices and links to the most recent documentation resources available. 2 NI-VISA Server 4. Hold down the RESET button. 143 likes · 13 talking about this. I want to use both modules together to get real-time data from different sensors. Making cRIO 9014 Wireless gtrevino80. The issue happens when you close a TDMS file reference, the vxWORKS OS is unable to properly unload. I have the console output of the 9014 on Hyperterminal and see that it is infact booted normally (NOT in Safe Mode) and is waiting to be configured. x. Interesting problem, same which I had to tackle yesterday, and on 9073 too, with the 0. MandA has succesfully detected the controller. I am also able to read temperature data from the thermocouples by means of NI Distributer System. If you are connected to the target, right-click the chassis in the project and select Deploy. The cRIO Information (CRI) component provides VIs to retrieve information about a local or remote cRIO controller, backplane, and modules including the type and serial number of each of these system components. We are using LabVIEW 2009 SP1. NI cRIO-9014 (CompactRIO Real-Time Controller) NI cRIO-9104 (FPGA and chassis) NI 9264 (16-Channel, +-10V, 16-Bit Analog Voltage Output Module) I have made a very simple FPGA VI: a while loop, Sine Wave Generator and a FPGA I/O Node in the loop. vi from the LabVIEW examples and add them to a project with a cRIO 9014. Hence, the system will not allow further configuration before it has been. Properties. 20并且获得了cRIO-9014 控制器。我已经使用了几个月,并且最近重新格式化了控制器,发现我无法从Measurement and. Detecting external USB drive mounting. ini file from the controller to your Windows machine. Press Open. -NI - cRIO-9014-NI - 9512 (for contorlling the motor)-NI - 9215 . . 33 GHz Dual-Core CPU, 2 GB DRAM, 32 GB Storage, Xilinx Spartan-6 LX 45 FPGA CompactRIO Controller (Legacy)—The cRIO‑9076 is an embedded controller ideal for advanced control and monitoring applications. Using the wrong kind of cable results in signals being written and read through unexpected pins, which usually. Compatibility between Xilinx Compilation Tools and NI FPGA Hardware - NI. i need to get to the FPGA of my cRio 9014 chassis 9112 module 9263. We intend to use LabVIEW 2023, therefore we will require CompactRio. The cRIO-9024 is an embedded real-time controller ideal for advanced control and monitoring applications. This document describes how to connect the NI cRIO-9012/9014 real-time embedded controllers to networks and how to use the features of the controllers. The cRIO-9012/9014 requires an external power supply that meets the specifications in the Power Requirements section. 5. Thus, NI-9881 is not supported when used in cRIO-910x or cRIO-907x reconfigurable chassis but only in cRIO-911x chassis or in cRIO-903x, 904x, 905x, 906x and 908x integrated controllers. cRIO-9014. LabVIEW LabVIEW Real-Time Module. Hence i would like to change appliation using console terminal. Note Older model chassis, such as cRIO-902x, cRIO-907x, cRIO-908x, NI 9144, and NI 9148, have HSI support on slots 1 through 4. implementation of HCC is done using NI-cRIO-9014. I was using labview 2011 FPGA module to build an interface with cRIO-9022, I have installed LabVIEW 2011, LabVIEW Real time module, LabVIEW FPGAmodule and NI-RIO version 4. Power on the controller, and observe the output on the PC's terminal window. I am using FIFO to plot the current sensor input to one of the analogue inputs. dual supply (Qty 5) P/N: 196938-01. The trick was to minimize TDMS Writes. Download. 5 professional development suit and other required software on my computer). I'm actually working with LV 2009 SP1 and Real Time and FPGA modules to develop on cRIO 9014 and 9024 controllers for CAN Bus applications. Some IT software block IPs considered invalid (Ex: cRIO-9014 when resetting IP assigns 0. 0). 0. Power on the controller, and observe the output on the PC's terminal window. I am trying to use old controller cRIO-9014 to create a test project on LabVIEW. MAINS voltage. LabVIEW 2011 SP1 FPGA Module or later. The only signals I have are three PWMs (using FPGA) being sent to three eurotherm solid state relays (which then control the three different bands of a furnace). But the problem is, I can't install Xilinx compilation tool 2015. Return to Home Page; Toggle navigation; Solutions. Open a service request. (attached FPGA code and other screenshots) It works fine at target rate up to 500Hz. (Once every 10 ms would be ideal, but we can tolerate 20 or 30ms. These also. Fast Quotes & Shipping. You can connect USB mass-storage devices to the cRIO-9012/9014 while the controller is operating. I format the cRIO disk, install the new version software, re-compile all my application (FPGA and RT layers), deploy all, reboot the cRIO. ? If someone has any example vi or reference please share. We have a CRio 9014. We have an existing setup working on Crio-9014 (Legacy) which is currently running our existing system. . 74) watts or 12. 254. Options. I am trying to get analog data from sensor with NI-9219. 06-05-2019 06:11 AM. 0. Thanks, your help is much appreciated. When I click the Run arrow, I get this message: Deploying variables - state machine. Solution. Open the Simple Data Server. PCN Title: National Instruments cRIO-9002 and cRIO-9004 Processor Change Notification Description of Change: The processor speed of the NI cRIO-9002 and NI cRIO-9004 controllers will. The cRIO-9014 has a high-speed USB port for the connection of USB-based external storage media (flash controllers and hard disks). However, I'm facing an issue where the module isn't showing up in NI. Please select your country. I'm using a cRIO-9014 with Scan mode, i need to reboot it programmatically (LV 8. Max Crash. Figure 4: cRIO-9014 Streaming 1D Wfm Data to Different File Formatsacquire waveform on scan engine mode cRIO 9014 . C. When streaming data to a cRIO controller's local drive, there are many questions and considerations. Basically they. Member 04-22-2020 04:31 AM. There is also one serial port available in this controller. Hi, I am using LABVIEW FPGA to collect some data (500 msec loop timer). crio-9012/9014/9074コントローラの操作手順マニュアルには、次のような趣旨の記述があります。「gpsのドリフト修正とsmb. Is there a fix for this? MAX 4. 1. If you are using the cRIO-9012/9014 in Gas Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. You can see the difference if you compare the 9073 ini file you. zip to try to get it ported over to my target but the 9403 module doesn't support the methods in the example. General. )National Instruments 783832-01 Dual Core Controller with ZYNQ-7020 FPGA and Extended Temperature. Hueter. Is it a problem with the rio chassis. Simply it doesn’t detect at all. cRIO-9014 and NI-9403. The NI cRIO-9012/9014 High-Performance Real-Time Controllers feature an industrial 400 MHz Freescale MPC5200 real-time processor for deterministic and reliable real-time applications. The NI cRIO-9012 and cRIO-9014. 168. Thus, NI-9881 is not supported when used in cRIO-910x or cRIO-907x reconfigurable chassis but only in cRIO-911x chassis or in cRIO-903x, 904x, 905x, 906x and 908x. 01-24-2016 06:34 AM. Active Participant. Is the. 0. The location for all firmware files is <Program. 0 )。然后,您可以使用提供dhcp服务器的任何网络点或设备. 1, LabVIEW Real-Time 15. Page 7 Connecting Serial Devices to the cRIO-9012/9014 The cRIO-9012/9014 has an RS-232 serial port to. Start a Review. If this is applicable, use any network point or device that provides DHCP server so that the cRIO receives a valid IP address. How can fix the problem ?arinc & 1553 . Si necesita reinstalar software en el controlador, de formato al disco y mediante FTP coloque el contenido del folder 9014 (del disco de instalación 2) en el controlador. how to proceed . Contact us. The FPGA is loaded programmatically by. 0. lvpro. Time zone is an issue for my application. For Real-Time targets, you can verify the version and reinstall the Real-Time software using MAX. Does LabVIEW 2020 support the cRIO-9014? If so, how can you make them work in conjunction? 0 Kudos Message 1 of 3 (788 Views) Reply. 0. com b. Order by Part Number or Request a Quote. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Find complete product documentation to learn how to get started and use the product. This is the same process used for adding modules to the FPGA Target in FPGA Interface mode, described above. All data was logged for later review and traceability. 0 address thing (the earlier 9073-family from P/N-looks of it). The analog signal from the 9239 card has a DC offset of 4-5mv which is way too much for my application. cRIO-9012 cRIO-9014 cRIO-9022 cRIO-9023 cRIO-9024 cRIO-9025 cRIO-9063 cRIO-9064 cRIO-9065 cRIO-9066 cRIO-9067 cRIO-9068 cRIO-9072 cRIO-9073 cRIO-9074 cRIO-9075 cRIO-9076 cRIO-9081 cRIO-9082 N/A Cable & Accessories for C Series Module with D-Sub connectioncRIO-9014. Hi all, I'm having a curious problem with the cRIO-9040 and cRIO-9045. 0. I've tried the old fashioned way as well (empty project - >new target etc). Cloudy with occasional showers overnight. . Under Devices and Interfaces in MAX I get a VISA error, which obiously is because I don't have any connection. National Instruments cRIO-9104 Reconfigurable 8-Slot CompactRIO Chassis. 0. Contact us. NI cRIO-9024 Real-time controller. The cRIO-9014 is a Real Time Controller, in other words a mini-computer. lvproj file and all VIs in a zip archive)? Can you connect to the cRIO within Measurement and Automation Explorer? Does the cRIO have the same version of software installed as you have on your computer? You can update the software on the cRIO from within Measurement and Automation Explorer. 2. 5. In the FPGA (included as a screenshot below), for the NI 9237, I have the excitation voltage set to 10 V, the data rate set to 25 kS/s, and the Enable Half-Bridge and Offset Cal set to false (I wasn't sure if the. The cRIO-9012/9014 does not since recently, I cannot connect to my cRIO 9014 via Ethernet. 0 to Gigabit Ethernet adapter Ip: 169. 2. I installed student version of LabVIEW 2021, opened NI Max and formatted the previous data from cRIO-9014 (as somebody else was using this controller for their project). This seems to be no issue of the cRIO(9014) but of the Xilinx software together with NI. 0 )。然后,您可以使用提供dhcp服务器的任何网络点或设. MAX lists the cRIO controller as the model name of the controller followed by the MAC address, for example, NI-cRIO-907400802f10856. 400 MHz CPU, 128 MB DRAM, 2 GB Storage, Extended Temperature CompactRIO Controller (Legacy)—The cRIO‑9014 is an embedded real-time controller ideal for advanced control and monitoring applications. LabVIEW Real-Time 8. 6 with cRIO 9014, NI 9103 chassi with c series NI 9215, NI 9263 and NI 9403 modules. Power on the cRIO by plugging the power back in (continue to hold the RESET button while powering on) Wait until the status light turns on, then release the RESET button. The operating range of the unit is up to 70C. I tried to compile and deploy one of the NI FPGA examples using my cRIO 9014 module. 74) watts or 12. 0, requiring a local config via MAX General advice: network settings should be preserved if possible. If you are using the cRIO-9012/9014 in GasProvides support for Ethernet, GPIB, serial, USB, and other types of instruments. 0. 173, subnet: 255. 03 ATEX 0324020X and is IECEx UL 14. 一部のitソフトウェアブロックipが無効と見なされます(例:ipをリセットするとcrio-9014が0. I created a blank project and added cRIO-9014 in the new target and device option. I'm trying to connect the CRIO 9014 module to my PC using an Ethernet cable. 10-12-2023 03:28 AM. I've gone through the manual and installed all the necessary drivers, including LabVIEW Realtime, LabVIEW FPGA, and NI MAX, on my PC. 2. - CRIO-9014: Manufacturer: Part # Datasheet: Description: National Instruments Co. Open a service request. I have a cRIO-9102 chassis with a cRIO-9014 controller. . I have been using my cRio 9014 with 9104 and some 9237 modules for a while now. In attachement I added a screenshot of the MAX window . I'm using a cRIO 9014 to read and save voltage data from a number of different sensors (thermocouples, load cells, pressure transducers) and want to save directly onto the cRIO. I am using four channels of Ni 9222 for the data measurements (hence sampling rate per channel should be 500/4 = 125S/s). 6. We have a project that causes very high CPU load due to fast frontpanel accesses with LV2014. Low 58F. 6. 2, NI 9882, cRIO 9014/9114). vi" (which runs on the RT target)refers to a number of subvi's that can not be found. 6 with CRIO 9014 and 9103 fpga chassi. This synchronization provides timestamp data to the controller. The direct current control HCC technique is designed in cRIO for generating gate control switching signals to drive the fuel cell power system. 165variables - state machine deployment faile. Naamloos. The cRIO-9012 (Part number: 779563-01) is a CompactRIO Controller by National Instruments. P/N: 196939-01. 6. If this is applicable, use any network point or device that provides DHCP server so that the cRIO receives a valid IP address. No ratings or reviews yet No ratings or reviews yet. NI-9219 AI Module. This rugged, fanless controller features a variety of connectivity ports, including one Ethernet, one USB, and. Refer to the Software Support for CompactRIO, CompactDAQ, Single-Board RIO, R Series, FlexRIO, and EtherCAT support document on ni. For example, if you are using the cRIO-9081, there is a section titled Installing an Operating System in the user manual, which outlines the steps. CompactRIO 平台包括带有工业浮点处理器的cRIO-9002 和cRIO-9004 实时控制器。cRIO-910x 系列的4 槽和8 槽可重新配置机箱具有1 百万或3 百万门FPGA,以及从±80 mV热电偶输入到250VAC/VDC 通用. 254. Re: IEC 61850. PRT - 779564-01 STP - 779564-01 IGS - 779564-01 Product Support Resources. I have cRIO 9014 with NI cRIO-9103 chassis. 0. Crio File System and Deployment. Experienced. To. The valve can be controlled with an input of 0- 10v. Install just the LabVIEW Real-time Module to the cRIO no additional package. 6. . I have been dealing with NI cRio 9014. 0. However, on my other computer, I faced with inconsistent IP problem. cRIO-9014 National Instruments cRIO-9014 High-Performance Real-Time Controller from National Instruments | Buy Today from Artisan. The cRIO-9014 is reliable and suitable for real-time operation, and it makes it easy to perform strain, tensile, and compressive load signal measurements and servo valve control output. cRIO 9103 FPGA backplane. cRIO-9014 EPICS. I am using cRIO 9014 and NI-9403 DIO module connected on my chassis. That means writing each "Group" in one write call, feeding it a giant pre-processed 2D array of. 2a is cRIO running RT and shared memory talking to a full IOC running on VxWorks. Additional Information The unconfigured state of the cRIO-9012/9014 implies that the cRIO has recently reset its IP settings to default. 0. SAN JOSE, Calif. The design uses a cRIO-9014 coupled with a cRIO-9104 as the base of the system (this could easily be replaced by a different cRIO controller or a different backplane) with an NI-9212 thermocouple module and an NI-9472 DIO module. Trusted Enthusiast 05-04-2012 01:54 PM. Mark as New; Bookmark; Subscribe; Mute;I am new to crio, I have a crio 9014 and a DO module 9474, I need to generate a PWM of 140 Hz and variable duty cycle between 5% to 95%. This document explains how to install and configure the AKD servo drives for use with the NI 9514 and. I've installed the software again. LabVIEW. Munkhaus Certified LabVIEW Developer (CLD) System Engineer 0 Kudos Message 21 of 33 (5,403 Views) Reply. My problem shortly. . 0 Kudos Message 1 of 4 (4,512 Views) Reply. DEMKO 03 ATEX 0324020X. File Size: 117Kbytes. This page is part of the CompactRIO System Accessory Compatibility Guide. The 9014 cRIO normally runs at around 50% CPU usage and less than 40% memory usage when the data is flowing steadily. I also have a separate control software I can use for manipulating these during the setup to make them start and stop communicating. I would like the sat the time between the status (orange, yellow) LED finish blinking and the first action made by the real time executable. Active Participant. Example code from the Example Code Exchange in the NI Community is licensed with the MIT license. Every example I have found at NI won't work with the 9403 because of method restrictions to the module. Can I acquire a voltage WAVEFORM with a cRIO 9014 set up in Scan engine mode? Im using a NI 9215 module (+-10V, 16-bit, 100Ks/s, Simultaneout Analog Input) . The IP address of the adapter needs to be in the same subnet as the IP address of the cRIO. NI 9870 RS-232 serial module. When I configure the scan engine mode on the cRIO, it says that the scan period should be higher than 1 ms in order to keep stable the cRIO. 0. Re: MAX can't find cRIO-9014. Mark. 1 My simulink model works when i run it on the pc, both as a simulation enviroment and whit the . NI-RIO 3. Active Participant 10-26-2011 10:27 AM. Page: 4 Pages. Basically I'm using LabVIEW 2011, NI cRIO-9118 Chassis, NI cRIO-9014 Real-Time Controller, one NI-9205 module (for Displacement), three NI-9239 modules (for Acceleration), three NI-9236 modules (for Strain Gages), and one NI-9401 module (TTL for indicators). I've connected and disconnected several times. If this is applicable, use any network point or device that provides DHCP server so that the cRIO receives a valid IP address. The controller automatically attempts to connect to the network using DHCP. . 1 はこちらからダウンロードできます。コントローラの問題. If you would like to have OPC UA functionality on a controller running Phar Lap. item 3 National Instruments NI cRIO-9014 CompactRIO Real Time Controller 4 or 8 Slot National Instruments NI cRIO-9014 CompactRIO Real Time Controller 4 or 8 Slot. But when I click the item in Devices and Interfaces, it shows an error:NI-9474 - 0. 5. This software-designed controller features an FPGA, a real-time processor running the NI Linux Real-Time OS, and embedded user interface capability. Active Participant. The chassis can be added as a stand-alone target to a Windows-based system or used as remote expansion I/O for systems based on NI LabVIEW Real-Time such as NI. Solved! Go to Solution. I have a cRIO-9074 and an ethernet RIO NI-9149. (Ej: cRIO-9014 cuando se restablecen las asignaciones de IP 0. 0. I'm not experienced in using cRIO. 4. 0 NI-VISA 4. I have tried using Labview 18, and have just tried version 19, but without success. 6 and vista 64. 58 + 0. NI 9979. I am using windows 7 andThe cRIO-9012/9014 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. 0. this opens the flow rate at the particular voltage and allows air to be release from the unit. 0 Network Variable Engine NI-RIO 3. To fix this problem, try the following steps: Delete the device from MAX by right-clicking on the remote target in MAX and clicking Delete. MUX version = 5. The RT System Monitor did not indicate a spike in either before the cRIO disconnected. 5 and NI-RIO 2. Figure 4 shows the experimental waveform of output voltage of a single-phase fuel cell system that uses NI-cRIO-9014 from National Instruments. To take advantage of all the features and capabilities of a PAC, it is fundamen-Hi I have a realtime data acquisition project with cRIO 9014, It was working fine and suddenly I am getting these errors 62 and 56 with TCP send receive. Downloadable Technical Manuals and Datasheets. The inverter output voltage waveform is shown in Fig. 01-29-2009 06:46 PM. 2. PDF - 779564-01 DXF - 779564-01 3D CAD Models. 625 + 0. Is it possible to implement this same function on a real-time target like a cRIO runing labview real-time 2009. And the module doesnot have a virtual folder when i try to discover the modules in the project explorer window. Most of the time when MAX will crash when the mouse is clicked over the cRIO-9014 icon under remote systems. I'm working on a Windows 10 laptop and I'm trying to acquire data from a NI 9214 thermocouple module with a cRIO 9014, connected with Ethernet cable. This may be necessary for the following reasons: To reset the password for the target. The cRIO-9014 (Part numbers: 779564-01 and 779564-02) is a CompactRIO Controller developed by National Instruments. ni application webserver 11. 0. This rugged, fanless controller features a variety of connectivity ports, including one Ethernet, one USB, and. I think there's an issue with the network adaptor because the Link/Activity indicator on the Ethernet port is always solid yellow (it should be blinking). I had a workign system which includeded a crio. IDC cRIO-9116 cRIO. Under the . In my RT code I have a DMA FIFO write with an infinite timeout within a timed loop. These ports include USB, Ethernet, and a serial communication terminal. Reference this information to ensure you install the correct version when upgrading or updating your operating system, or when migrating or porting code to a new system. 5 and VISA 4. Update with NI MAX: Open NI MAX. 1, and the CompactRIO Device Drivers 15. 0. 8). Now i've switched to LabVIEW 2009 and NI-RIO 3. The cRIO-9014 (Part numbers: 779564-01 and 779564-02) is a CompactRIO Controller developed by National Instruments. llb file for 61850. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;I have a cRIO-9014 system and am trying to communicate with a device through the built in serial port. 1. NI-9237 - 0. One of the PMW should be analogue with voltage range 0 -1 and the other digital. But it doesnt work higher target rates. I'm using a cRIO-9014 with Scan mode, i need to reboot it programmatically (LV 8. g. 0 Kudos Message 4 of 9 (3,223 Views. According to our Labview code, FPGA target of the controller would trigger to. I have received instructions from the company that manufactured the equipment but they are leaving out a lot of information. Hey there, we have sensors on an Engine which are connected to a NI cRIO 9014 board (with a NI9411 6-channel digital input modul) and go from there via network to a host computer. Hi everyone, I am trying to generate pulses that I can change the duty cycle. vi and the Simple Data Client. Use this guide to select the correct MXI-Express cable for your CompactRIO Controller. cRIO-9040 cRIO-9041 cRIO-9042 cRIO-9043 cRIO-9045 cRIO-9046 cRIO-9047 cRIO-9048 cRIO-9049 cRIO-9053 cRIO-9054 cRIO-9056 cRIO-9057. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. 0. Hi, I am using NI 9221 modules on CRio 9014, whn I am trying to write the data in the test file using I am getting an error 1430 occured atThe root of this issue is the relatively low internal memory of the cRIOs of the 901x, 907x and 906x series. test-ni-rt. Can you transfer the files using Windows Explorer (assuming your development environment is Windows)? Response: Yes. 4. Provides support for NI data acquisition and signal conditioning devices. I am trying to run one of the 61850 examples on my cRIO 9014 (access BCR. Select the firmware version you want to update and click Open. The extreme speed of the explosions requires the full capabilities of the cRIO, sampling at much higher than the typical 1000 Hz limit of other competing acquisition systems. Until this Stream to Disk Benchmarks for cRIO controllers whitepaper is updated for the cRIO-9068, any idea on the change in throughput we can expect compared to VxWorks and Pharlap cRIO targets, understanding there are. I use LabVIEW 8. The NI cRIO-9012 and cRIO-9014 controllers combine the productivity of LabVIEW Real-Time and the reliability of the VxWorks device software, making it easy for engineers to rapidly design embedded systems. The. Then, I run the windows VI to see the voltage plots read from. Hola Brand, Gracias por responder, afortunadamente cuendo con un cRIO 9031 con NI Linux RT y funciono perfectamente. The subsequent figures show the same results for the cRIO-9074 and the cRIO-9022. I'm trying to connect the CRIO 9014 module to my PC using an Ethernet cable. x. The Software installation is probably corrupted: Right Click > Delete the cRIO in NI MAX and add it again. This rugged, fanless controller features a real-time processor and an FPGA and offers a variety of connectivity ports, including one. 400 MHz CPU, 128 MB DRAM, 2 GB Storage, Extended Temperature CompactRIO Controller (Legacy) —The cRIO‑9014 is an embedded real-time controller. This model is used to control and monitor C Series applications. Mark as New; Bookmark; Subscribe; Mute;I'm new to working with the NI CRIO 9014 module. Order by Part Number or Request a Quote. The obtained results were. Hello, I am working with NI cRIO 9014 along with 9104 chassis. Options. 02-20-2013 04:57 PM. Comprehensive company profiles. GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules Note If you are a new user of LabVIEW or are unfamiliar with LabVIEW, refer to. I doubt that the RT-clock is continuosly updated, because if I change time and/or date with"RT Set Date And Time. Set Speed (baud rate) to 9600. Each cRIO-9012/9014 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. . Windows XP 32bit . out-file cannot be loaded on the controller. I'm surprised by the cRIO executable starting time after reboot. 0. NIについて. This page is part of the CompactRIO System Accessory Compatibility Guide. I'm new to working with the NI CRIO 9014 module. The NI cRIO 9104 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status. I also created a shared variable array to use it on the cRIO host. cRIO - 9113. Hi everyone I am using a cRIO 9014 with NI 9239. A valid service agreement may be required. Support for SNTP clock sync was added in LabVIEW Real-Time module 8. 2) I wrote a VI which listens for NTP clients and sends a NTP package back, if the requesting IP is in the IP list of allowed clients. 0). 12-03-2013 11:56 AM. 2 Run time engine for web services 2. Set Speed (baud rate) to 9600.